How to choose vacuum magnetic valve

How to choose vacuum magnetic valve

(Summary description)1. Economy of vacuum magnetic valve.There are many vacuum magnetic valves that can be used in general, and the most economical product should be used in the selection process.

How to choose vacuum magnetic valve

(Summary description)1. Economy of vacuum magnetic valve.There are many vacuum magnetic valves that can be used in general, and the most economical product should be used in the selection process.

Information

  1. Economy of vacuum magnetic valve

  There are many vacuum magnetic valves that can be used in general, and the most economical product should be used in the selection process.

Vacuum magnetic valve

  2. Security

  Generally, the vacuum magnetic valve is not waterproof. If the conditions do not allow, please choose the waterproof type. The factory can customize it. The highest rated nominal pressure of the solenoid valve must exceed the highest pressure in the pipeline, otherwise the service life will be shortened or other unexpected situations will occur.

  3. Reliability

  vacuum magnetic valves are divided into two types: normally closed and normally open; generally, the normally closed type is used, which is opened when energized, and closed when it is powered off; but when the opening time is very long and the closing time is very short, the normally open type should be selected. The life test is generally a type test project in the factory. To be precise, there is no professional standard for solenoid valves in my country, so be careful when choosing solenoid valve manufacturers.

  4. Applicability

  The fluid in the pipeline must be consistent with the medium calibrated in the selected vacuum magnetic valve series model. The temperature of the fluid must be less than the calibration temperature of the selected solenoid valve. The allowable liquid viscosity of the solenoid valve is generally below 20CST, and it should be indicated if it is greater than 20CST. Generally, the vacuum magnetic valve works in one direction, so pay attention to whether there is a back pressure difference, if there is a check valve installed.

  vacuum magnetic valves are generally only controlled by two switches; if conditions permit, please install a bypass pipe to facilitate maintenance; when there is water hammer, the opening and closing time of the solenoid valve should be adjusted. Pay attention to the influence of ambient temperature on the solenoid valve. The power supply current and power consumption should be selected according to the output capacity. The power supply voltage is generally allowed to be about ±10%. It must be noted that the VA value is relatively high during AC starting.

Keyword:

Scan the QR code to read on your phone

zapa

Conatct

Tel:+86 18930867676

Add: Room 1820, Block B, Red Star World Trade Building, No.598, Nujiang North Road, Putuo District, Shanghai

zapa

Jobs

Zapa always believes that talents are the invincibility of the company in the market
Core resources

zapa

Talent Concept

Zapa always believes that talents are the invincibility of the company in the market
Core resources

Copyright:Shanghai ZaPa Vacuum Technology Co., Ltd.  - 2020 All Rights Reserved. 沪ICP备18006805号 Designed By:www.300.cn